Working conditions and working environment for TRUCK SCALE

·  Working environment Humidity: 10%~95% (not condensed)
·  Working power: 220 VAC (-15% ~ +10%), 50Hz ± 2%
·  Working environment temperature: load cell: -20 ℃ ~ +65 ℃ indicator: -10 ℃ ~ +40 ℃
·  Use in the occasion that have explosion prevention environment requirement, can order intrinsic safe and explosion-proof type truck scale.
 
Specifications series
 
Maximum capacity series (t) 20 30 50 60 80 100 120 Weighing platform module Weighing platform
Number of division 2000 3000 2500 3000 4000 5000 6000
Number of element
Units combination
Actual size
Division value (kg) 10 10 20 20 20 20 20
Class of accuracy
Platform size (m) 3X8           2-4+4 3×8
3X10         2-5+5 3×10
3X12       2-5.8+5.8 3×11.6
3X15         3-5+5+5 3×15
3X16         3-5.8+5+5 3×15.8
3X18       3-5.8+5.8+5.8 3×17.4
3X21           3-5.8+5+5+5 3×20.8
Attention:
1. The difference of weighing platform actual size and nominal size mainly due to
that 6m module is designed to be 5.8m expressly for adapting to container transport.
2. According to user’s requirement, total length of weighing platform nominal size can be combined otherwise that increment is 1m.